| Part Number |
Operate Point (Oe) | Differntial (Oe)1 | Output | Marking |
Orientation |
Package | |||
| Min. | Max. | Min. | Max. | ||||||
| | |||||||||
|
AD821-00 |
|
15 | 25 |
5 | - |
Sink + Sink | MBB |
Cross-axis | |
| AD824-00 | 21 |
34 | 5 |
20 | Sink + Sink |
MBF | Cross-axis | ||
| AD822-00 | 30 |
50 | 5 |
25 | Sink + Sink |
MBC | Cross-axis | ||
| AD823-00 |
60 | 100 |
5 | 35 |
Sink + Sink | MBD |
Cross-axis | ||
| AD921-00 | 15 |
25 | 5 |
- | Sink + Source |
NBB | Cross-axis | ||
| AD924-00 | 21 |
34 | 5 |
20 | Sink + Source |
NBF | Cross-axis | ||
| AD922-00 | 30 |
50 | 5 |
25 | Sink + Source |
NBC | Cross-axis | ||
| AD923-00 | 60 |
100 | 5 |
35 | Sink + Source |
NBD | Cross-axis | ||
| Part Number |
Operate Point (Oe) | Differntial (Oe)1 | Output | Marking |
Orientation |
Package | |||
| Min. | Max. | Min. | Max. | ||||||
| | |||||||||
|
ADH025-00 | 8 |
12 | 2 |
8 | CSK |
MBL | Cross-axis | ||
1See digital component information for notes.
The NVE Digital Switch is available in various output arrangements, packaging formats, and sensitivities. The following table details how the part number is determined by the part’s configuration. Click on this link to see an expanded table of part number configurations.
Two directions of sensitivity are available with all parts. "Standard" direction of sensitivity is defined as the direction parallel to the edge of the package containing pins. "Cross Axis" direction of sensitivity is defined as the direction perpendicular to the edge of the package containing pins.
|
|
|
Package Marking
All SOIC packaged parts (-02 part number suffix) are marked with the correct part number on the package. Due to the limited space available on the TSSOP package (-00 part number suffix), these parts are marked with a code as listed in the Configuration Chart above.
Note 1: In the case of a standard axis part with the Vregulated pin option, Sink(1) will appear with the pin labeled N/C*.